630162_5EF5000InstallationGuideRemotion‐US
Installation Manual
EF5000 - US
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
DANGER - WHAT TO DO IF YOU SMELL GAS:
o Do not try to light any appliance.
o Do not touch any electrical switch; do not use any phone in your
building.
o Immediately call your gas supplier from a neighbour’s phone. Follow
the gas suppliers instructions.
o If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service
agency or gas supplier.
- Instructions must be left with the consumer and the consumer to retain
them for future reference
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing this equipment.
WARNING: For Outdoor Use Only.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which
has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as
a cam
p
er
,
tent
,
car or home.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from
the appliance and immediately call
your gas supplier or fire department.
WARNING
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other
appliance.
An LP-cylinder not connected for
use shall not be stored in the vicinity
of this or an
y
other a
pp
liance
pour les documents français vont à www.escea.com/technical
Przeglądanie stron 0
1 2 3 4 5 6 ... 21 22

Podsumowanie treści

Strona 1 - Installation Manual

630162_5EF5000InstallationGuideR‐emotion‐US Installation Manual EF5000 - US WARNING: If the informa

Strona 2 - Contact:

630162_5EF5000InstallationGuideR‐emotion‐US 8.0 Laying Gas Pipe: Gas pipe should be sized as per the requirements of your local council. The

Strona 3 - Contents: Page:

630162_5EF5000InstallationGuideR‐emotion‐US 9.0 Fixing the fire into the cavity: To fix the fire to the cavity, first drill 4 to 6 (3/16” d

Strona 4 - 1.0 Product Description:

630162_5EF5000InstallationGuideR‐emotion‐US 11.0 Connecting the power supply and Touch panel: 11.1 The Touch Panel and Power Isolating Swi

Strona 5 - 2.1 Replacing Batteries:

630162_5EF5000InstallationGuideR‐emotion‐US 13.0 Checking Operating Pressure: This appliance must be disconnected from the gas supply piping

Strona 6 - 4.0 Cavity Dimensions:

630162_5EF5000InstallationGuideR‐emotion‐US 14.0 Assembly of stone cartridge: The glass which fits inside in the stone Cartridge has been

Strona 7 - 7.0 Types of Installation:

630162_5EF5000InstallationGuideR‐emotion‐US 15.0 Fitting the Fascia: Before fitting the fascia, the hooks must be attached using the screws p

Strona 8

630162_5EF5000InstallationGuideR‐emotion‐US 16.0 Placement of ceramic stones: EF5000 fuel beds should be evenly spread out with a maximum on

Strona 9 - Corner Installations:

630162_5EF5000InstallationGuideR‐emotion‐US 17.0 Operating Instructions: The EF5000 is operated by the touch control panel located on the Righ

Strona 10 - Gas Pipe Entry Point

630162_5EF5000InstallationGuideR‐emotion‐US 17.4 Pilot Flame and Burner Positioning 17.5 Turning on the main burners Once the pilot f

Strona 11 - Connecting the Gas Pipe:

630162_5EF5000InstallationGuideR‐emotion‐US 18.0 Maintenance and Cleaning The unit must be cold before starting any form of maintenance or

Strona 12

630162_5EF5000InstallationGuideR‐emotion‐US Important: The appliance shall be installed in accordance with;  Local gas fitting and buil

Strona 13

630162_5EF5000InstallationGuideR‐emotion‐US EF5000ReplacementParts820100 Large White Ceramic Stones820132 Membrane Switch and Control Bracket82

Strona 14

630162_5EF5000InstallationGuideR‐emotion‐US 19.1 Operation Chart LPG Natural Gas Min. Inlet Pressure 10”wc 5.5”wc Max Inlet Pressure 20”wc

Strona 15 - 15.0 Fitting the Fascia:

630162_5EF5000InstallationGuideR‐emotion‐US LIMITED WARRANTY: Provided that the Product is installed as per ESCEA's Installation Manual an

Strona 16

630162_5EF5000InstallationGuideR‐emotion‐US Contents: Page: Product description 1.0 Powe

Strona 17 - 17.0 Operating Instructions:

630162_5EF5000InstallationGuideR‐emotion‐US 1.0 Product Description: The escea EF5000 flame effect gas fire is designed for outdoor use only.

Strona 18

630162_5EF5000InstallationGuideR‐emotion‐US 2.0 Power Supply: This appliance requires 3 ‘D’ sized cell batteries for operation, which are loca

Strona 19 - Part No. 620261_1

630162_5EF5000InstallationGuideR‐emotion‐US Ideal Cavity Dimensions A B C 39 13/16“ 23”

Strona 20

630162_5EF5000InstallationGuideR‐emotion‐US 5.0 Wall cladding around fire: 5.1 The temperature of the wall directly above the heater will g

Strona 21 - LPG Natural Gas

630162_5EF5000InstallationGuideR‐emotion‐US - Within a partial enclosure that includes an overhead cover and no more than two walls.

Strona 22

630162_5EF5000InstallationGuideR‐emotion‐US 7.1 Corner Installations: If a cavity is to be created in a corner, the following drawings give t

Komentarze do niniejszej Instrukcji